Ndeupi huwandu hwekuyerera kwevortex mita calibration?
Iko hakuna imwechete "yepasirese" yakanyanya kuyerera huwandu hwevortex mita calibration - zvinoenderana
saizi yemamita (DN), rudzi rwemvura (mvura/gasi//chitsinga), uye miganhu yevagadziri. Izvo zvakati, inoshanda calibration marenji uye velocity miganhu inotsanangurwa zvakanaka.
1. Yakajairika Calibration Flow Ranges (pamwe neJJG 1029 & ISO 12764)
- Zvinwiwa (mvura, nezvimwewo):
- Calibration range:0.3 ~ 700 m³/h(DN15–DN200)
- Max velocity:10 m/s
- Magasi (mhepo, gasi rechisikigo):
- Calibration range:0.5 ~ 7,000 m³/h(DN15–DN300)
- Max velocity:60–80 m/s
- Steam:
- Calibration range:0.4 ~ 28,000 m³/h(DN hombe)
- Max velocity:70–80 m/s
2. Miganhu Yakakosha Inotsanangura "Max Flow"
- Reynolds nhamba (Re):
- Minimum linear Re:2×10⁴(mvura) /4×10⁴(gasi/mupfu)
- Maximum Re:~7×10⁶(yepamusoro muganho wekuteura yakagadzikana vortex)
- Turndown ratio: Kazhinji10:1(kuyerera kukuru = 10 × min kuyerera)
- Optimal calibration zone: 20% -80% yemamita emhando yezita(10% -90% yemhando yepamusoro-yechokwadi)
3. Muenzaniso: DN100 Vortex Meter (Mvura)
- Nominal max flow:120 m³/h(≈4.2 m/s)
- Calibration range:12–120 m³/h(10:1 kufuratira)
- Optimal calibration points:24, 48, 72, 96, 120 m³/h
4. Calibration Standard Zvinodiwa
- Minimum test points: 6(kusanganisira min uye max kuyerera)
- Fluid: Shandisa chaiyo process fluid kana mvura inekuenzanisa nhamba yaReynolds
Muchidimbu: Nokuti
mvura, max calibration kuyerera kazhinji
~700 m³/h (DN200); nokuti
gasi,
~7,000 m³/h (DN300). Gara uchisimbisa ne
dheta remugadziriuye
calibration lab renji.