Does the precession vortex flow meter can measure standard condition flow?
Yes, it has temperature and pressure compensation and can display m3/h and Nm3/h.
-
What's the standard output of precession vortex flow meter?
4~20 mA + Pulse + RS485
-
If medium is 90℃, can it be measured by precession vortex flow meter?
No, Temperature of measured medium should be -30℃~+80℃, if more than -30℃~+80℃, thermal mass flow meter will be recommended.
-
What material of thermal gas mass flow meter?
Mainly is SS 304.client also could choose SS 316 and SS 316L according to working condition.
-
Thermal gas mass flow meter output
Standard output :DC4-20mA, MODBUS RTU RS485, Pulse.
-
How to calibrate thermal gas mass flow meter?
We all adopt Gas Venturi Sonic Nozzle Calibration Device to calibrate each gas flow meter.